Use casesIt’s up, but it’s bad

A circuit keeps flapping. Contain it, then make the carrier fix it properly.

A marginal circuit that bounces four to eight times an hour is worse than one clean outage. Contain it so traffic stops thrashing, then collect the evidence while it is still happening.

  • Timeabout 15 minutes
  • ForNOC engineer, Network lead, Finance and vendor management
  • ScreensExplorer, Remediation, SLOs, Noise Agent, Governed Brain

Recognize it

You’re here if

  • Availability toggles several times an hour, for short intervals.
  • Path-change counts on the tunnel are far above normal.
  • Alert volume for one site is climbing and users report resets.

Do this

5 steps, in order

  1. Confirm the pattern

    Pick the site and the Availability metric. Use the widest window.

    Open Explorer
    Look for
    Repeated short dips, several per day or per hour, with latency otherwise normal.
    What it means
    Normal latency between dips rules out the middle mile. This is the last mile or the media.
  2. Contain it

    Review the recommendation to dampen the path or pin the tunnel to the stable backup.

    Open Remediation
    Look for
    A reversible action with a rollback plan.
    What it means
    Keep the circuit out of rotation until its errors clear. A stable failover beats a flapping primary.
  3. Count it for the contract

    Open SLOs and find the link. Read actual availability against target and the error budget used.

    Open SLOs
    Look for
    Actual availability below the contractual floor.
    What it means
    This is the number for the credit claim.
  4. Quiet the noise

    Check that the cooldown and chronic policies are folding this flap into one alert instead of paging every bounce.

    Open Noise Agent
    Look for
    The flap collapsed to one situation with a recurrence count.
    What it means
    One page with a count beats forty pages.
  5. Push for a permanent repair

    Use the incident’s evidence on the carrier ticket. Ask for media replacement or connector reseat, not another temporary fix.

    Open Governed Brain
    Look for
    Dated failover events and an availability rollup.
    What it means
    Reweight this circuit as primary until it has been stable for a defined period.

Then decide

What you found decides what you do

  • IfDampening stops the storm

    ThenKeep the circuit parked and chase the repair.

  • IfMonth-to-date availability is below the contract floor

    ThenFile the credit claim with the dated evidence. Claim an SLA credit →

Watch out

Where this goes wrong

  • A flapping circuit can hide a second fault in the noise it creates. Re-check the site once the flapping is contained.
You’re done when

The circuit is contained, the contract number is written down, and a repair is requested with evidence.